National Repository of Grey Literature 6 records found  Search took 0.01 seconds. 
Signal Detection by Segmental Ionization Detector in Environmental SEM
Černoch, Pavel ; Jirák, Josef (advisor)
The dissertation thesis deals with signal detection by an ionization detector in the environmental scanning electron microscope and utilization of this detector to gain required information in a specimen image. Main interest is focused on the detector containing several electrodes with a varied geometry arrangement and voltages on these electrodes. The detector was named segmental ionization detector. Detection capabilities of the segmental ionization detector were studied through computer simulations and experiments in the microscope utilizing knowledge from a technical literature background. On the base of the accomplished experiments, the segmental ionization detector has been optimized for the secondary electron detection improvement and at another configuration optimized for a high material contrast acquisition of the specimen image. Consideration of benefits of the examined segmental ionization detectors is included in the work.
Methods for Quality of Service measurement in Wi-Fi networks
Bachan, Jiří ; Kolka, Zdeněk (referee) ; Prokopec, Jan (advisor)
This work deals with the wireless Wi-Fi networks, that used unlicenced ISM frequency band 2,4 GHz. These wireless networks are very extended in these days and used mainly for the Internet connection. With the multimedia data transfers expanding it’s necessary to ensure the specific quality of service QoS in wireless networks mainly for applications, which are sensitive to delay or packets lost. The main aim of this work is to describe Wi-Fi networks based on IEEE 802.11b/g/n standards, description of QoS techniques according to IEEE 802.11e standard and description of parameters describing QoS for the VoIP services. The practical part is divided on a two parts. The problems of measuring the radio link quality and the creation of simple program for quality of wireless connection analysis are solved in the first part. The second part incluledes measuring of the lost packets number in Wi-Fi network with the commercial application AirMagnet Laptop Wireless LAN Analyzer and measuring of the signal noise influence with the help of spectrum analyzer and vector signal generator.
Ionization detector for environmental scanning electron microscope
Melechovský, Ondřej ; Čudek, Pavel (referee) ; Jirák, Josef (advisor)
Presented work deals with environmental scanning electron microscopy. The construction of the device is described concisely in the beginning. Important part is devoted to interaction of electrons with specimen and signals emitted from the specimen. The work aims especially at detection of secondary electrons using the ionization detector. Experimentally is determined effect of working environment and size of electrode system of ionization detector on detected signal.
Ionization detector for environmental scanning electron microscope
Melechovský, Ondřej ; Čudek, Pavel (referee) ; Jirák, Josef (advisor)
Presented work deals with environmental scanning electron microscopy. The construction of the device is described concisely in the beginning. Important part is devoted to interaction of electrons with specimen and signals emitted from the specimen. The work aims especially at detection of secondary electrons using the ionization detector. Experimentally is determined effect of working environment and size of electrode system of ionization detector on detected signal.
Signal Detection by Segmental Ionization Detector in Environmental SEM
Černoch, Pavel ; Jirák, Josef (advisor)
The dissertation thesis deals with signal detection by an ionization detector in the environmental scanning electron microscope and utilization of this detector to gain required information in a specimen image. Main interest is focused on the detector containing several electrodes with a varied geometry arrangement and voltages on these electrodes. The detector was named segmental ionization detector. Detection capabilities of the segmental ionization detector were studied through computer simulations and experiments in the microscope utilizing knowledge from a technical literature background. On the base of the accomplished experiments, the segmental ionization detector has been optimized for the secondary electron detection improvement and at another configuration optimized for a high material contrast acquisition of the specimen image. Consideration of benefits of the examined segmental ionization detectors is included in the work.
Methods for Quality of Service measurement in Wi-Fi networks
Bachan, Jiří ; Kolka, Zdeněk (referee) ; Prokopec, Jan (advisor)
This work deals with the wireless Wi-Fi networks, that used unlicenced ISM frequency band 2,4 GHz. These wireless networks are very extended in these days and used mainly for the Internet connection. With the multimedia data transfers expanding it’s necessary to ensure the specific quality of service QoS in wireless networks mainly for applications, which are sensitive to delay or packets lost. The main aim of this work is to describe Wi-Fi networks based on IEEE 802.11b/g/n standards, description of QoS techniques according to IEEE 802.11e standard and description of parameters describing QoS for the VoIP services. The practical part is divided on a two parts. The problems of measuring the radio link quality and the creation of simple program for quality of wireless connection analysis are solved in the first part. The second part incluledes measuring of the lost packets number in Wi-Fi network with the commercial application AirMagnet Laptop Wireless LAN Analyzer and measuring of the signal noise influence with the help of spectrum analyzer and vector signal generator.

Interested in being notified about new results for this query?
Subscribe to the RSS feed.